Jinan Jinzhong Electronic Scale Co., Ltd.
Main products:Load cell,electronic truck scale,electronic platform scale,electronic floor scale,electronic crane scale,electronic railway scale,weighing indicator,strain gauge,weighbridges,bench scale
Products
Contact Us
  • Contact Person : Ms. Wu Melanie
  • Company Name : Jinan Jinzhong Electronic Scale Co., Ltd.
  • Tel : 86-531-82971354
  • Fax : 86-531-82971352
  • Address : Shandong,JINAN,NO,147, YINGXIONGSHAN ROAD, JINAN, CHINA
  • Country/Region : China
  • Zip : 250002

CZL-YB-**-ST Column Load Cell

CZL-YB-**-ST Column Load Cell
Product Detailed
Stainless Digital load cell Column/Compresion canister type. Easy for applied in mutiple load cell etc...

..CZL-YB type (made of stainless steel) column load cell is hermetically sealed,and has protection grade specified as IP68.It has high ability to correct core and prevent turning. Argon-arc welded, taking compression force, its dynamic reaction is good. Easily installed, it can be highly over-loaded and used in truck scale, motion railway scale, hopper scale and so on.

 

Sensitivity

mV/V

2.0±0.002

Accuracy class

 

C3

C2

Maximum number of load cell interval

 

3000

2000

Minimum load cell verification interval

 

Emax /10000     

Emax /7000    

Combined error

%F.S.

0.02

0.023

Repeatability

%F.S.

0.01          

0.015

Creep

%F.S./30min

±0.0245

±0.0245

Minimum dead load output return

%F.S.

±0.017

±0.025

Temp. effect on min. dead load output

%F.S./5

±0.007

±0.010

Temp. effect on sensitivity

%F.S./5

±0.007

±0.009

Minimum dead load

% Emax

1

Maximum safe overload

% Emax

125        

Ultimate overload

% Emax

300

Supply voltage

V

10∼15DC/AC

Zero balance

%F.S.

±1

Input resistance

Ω

1310±20

Output resistance

Ω

1000±3

Insulation resistance

≥5000

Compensated temperature range

 

-10∼+40

Operating temperature range

 

-30∼+70

Connect cable

mm

Φ6.7×13000

Method of connecting wire

Input+: Green    Input-: Black

Output+: White Output-: Red

  Sense+:Yellow  Sense-:Blue

Shield : Yellow

CZL-YB-**-ST Column Load Cell



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.